Drip Defender protects your foundation by continuously monitoring soil moisture around the perimeter and automatically triggering corrective irrigation before conditions cause structural damage. This guide covers everything from power wiring to soil sensor placement and device mounting.

Before starting: Complete the Device Setup Guide first to connect your device to WiFi and link it to your account.


Before You Begin

Tools needed

  • Trenching spade or power trencher
  • Wire strippers and crimping tool
  • Drill and bits (for valve box lid)
  • Screwdrivers (flathead and Phillips)
  • Measuring tape
  • Pipe wrench or adjustable wrench

Materials needed

  • Drip Defender device(s), one per foundation zone
  • Transformer, 300 W, 120 VAC input, dual-output: 24 VAC (for 24 VAC hold solenoid valves) or 12 VAC (for 12 VDC latching solenoid valves) (sold by Telemetry Insights or customer-supplied)
  • 2-conductor direct-burial wire, 14–16 AWG (runs in the same trench as the irrigation pipe)
  • Splice connectors, one per device tap point
  • Underground valve boxes, one per device location
  • Foundation perimeter solenoid valves, 24 VAC hold or 12 VDC latching
  • Irrigation pipe, 1/2", 3/4", or 1" (procured from third-party suppliers). Pipe size should match your solenoid valve size. Both 24 VAC hold and 12 VDC latching solenoid valves are available in 1/2", 3/4", and 1".
  • Manual shut-off valve for the main supply line
  • Drip tubing and emitters, or short-throw sprinkler heads for each perimeter zone

Existing transformer? You can use your own if it supplies 24 VAC (or 12 VAC for latching solenoids) with sufficient wattage. Budget 20 W per device with 24 VAC hold solenoids. A 300 W transformer supports up to 12 devices on a single run, depending on cable gauge and run length.


Power System Overview

Each Drip Defender device draws power from a single landscape cable run from the transformer along the foundation perimeter. Each device taps power at its installed location via a splice connector, no individual runs back to the transformer.

Power options

SourceSolenoid typeBudget per device
24 VAC24 VAC hold solenoid valve (most common)20 W
12 VAC12 VDC latching solenoid valve10 W

Wiring

  • Cable type: 14–16 AWG 2-conductor direct-burial wire, run in the same trench as the irrigation pipe
  • Route: One continuous cable run from transformer along the full foundation perimeter
  • Tap method: Splice connector at each device location, no return runs needed

USB power packs are not for permanent installation. Use a USB power pack only during initial device setup.


Step 1 - Trench, Lay Pipe, and Run Wire

The irrigation pipe and the 2-conductor power wire share the same trench. Plan and dig the full perimeter trench before placing either.

  1. Plan device locations around the perimeter, typically one device per foundation zone or corner.
  2. Install a manual shut-off valve on the main supply line before it branches to any perimeter zones. This allows you to isolate the system for maintenance without shutting off the entire property water supply.
  3. Trench along the perimeter at a depth below the local frost line to prevent water in the pipes from freezing. A minimum of 12 inches (30 cm) is typical for mild climates; colder regions may require 18–24 inches (45–60 cm) or more.
  4. Lay the irrigation pipe in the trench along the perimeter, connecting back to the manual shut-off and supply.
  5. Lay the 2-conductor direct-burial wire in the same trench alongside the pipe, running continuously from the transformer through each device location. Do not cut individual runs, one continuous wire feeds all devices.
  6. Leave a service loop of extra wire (~12 inches / 30 cm) at each device location for splicing.
  7. Leave the trench open until all installations are complete and tested.

Water pressure: Each device waters independently based on its own soil moisture readings and AI recommendations. There is no coordination or staggering between devices. Simultaneous activation of all zones is unlikely in practice, but not prevented. Size your supply pipe accordingly. Run the trench at least 6 ft (1.8 m) from the foundation wall so it does not interfere with the drip emitters or sprinkler heads placed at the base of the foundation.


Step 2 - Install the Valve Box

Each device installs inside an underground valve box. The valve box has no bottom and has curved side openings for irrigation pipe entry and exit. The device mounts to the inside of the lid and is accessible from the surface without digging.

  1. Dig a hole at each device location sized to fit the valve box, with the top flush with or slightly above ground level.
  2. Set the valve box in the hole. The box houses the solenoid, soil sensor, and device wiring.
  3. Route the landscape cable service loop into the valve box.

Step 3 - Install the Solenoid and Zone Heads

The solenoid valve controls the foundation perimeter zone and installs inside the valve box on the irrigation supply line.

  1. Place the solenoid valve in the bottom of the valve box, routing the supply pipe through the side opening to the solenoid inlet.
  2. Connect the solenoid outlet to the zone pipe that exits through the opposite side opening and feeds the perimeter drip emitters or sprinkler heads (a single device and valve can feed multiple drip emitters and/or sprinkler heads).
  3. Route the solenoid wire leads up to the device terminal block inside the valve box.

Match solenoid type to your transformer output tap. The 24 VAC output tap pairs with the 24 VAC hold solenoid. The 12 VAC output tap pairs with the 12 VDC latching solenoid. The device rectifies the 12 VAC input to 12 VDC internally. Mismatching transformer output tap and solenoid type will result in the solenoid either failing to open or burning out, and may damage the device. Check the solenoid spec sheet if unsure.

Compatible heads

A single Drip Defender device can feed multiple heads in its zone, drip emitters, short-throw sprinkler heads, or a mix of both, based on available water pressure and pipe sizing. Drip emitters are preferred along the foundation wall for precise, low-pressure delivery. Short-throw sprinkler heads work well where the coverage area is wider or where emitter placement is difficult.

Pipe size should match your solenoid valve size (1/2", 3/4", or 1") and be sized to deliver adequate pressure across all drip emitters or sprinkler heads in the zone. Larger pipe supports more irrigation points. Solenoid valves in all three sizes are available from Telemetry Insights in both 24 VAC hold and 12 VDC latching types. All pipe, fittings, and valves can also be sourced from any third-party irrigation supplier.


Step 4 - Install the Soil Sensor

Proper sensor depth is critical for Drip Defender. The goal is to measure soil moisture at the level where foundation stress occurs, near the depth of the foundation footing. The recommended depth for your foundation type is shown in the Moisture Sensor Installation section of the device configuration page. The table is a starting point. Adjust based on your specific site conditions and foundation type.

Placement

Place the sensor within 6 inches (15 cm) of the foundation wall. This is the recommended starting point. Adjust based on your site conditions and foundation type.

Installation

  1. Position the probe within 6 inches (15 cm) of the foundation wall at a depth between 18 inches and 15 feet. Dig a hole using a post hole digger, hand auger, or shovel. Lower the sensor into the hole until the tines rest on the bottom at the target depth. All tines must be fully in the earth and not exposed to air. The standard sensor cable is 6 ft. Account for the length needed to run from the sensor up to the device in the valve box; in practice this leaves approximately 3 ft of usable depth on the standard cable. For greater depths, extend the cable using a waterproof splice up to 20 ft total before routing up to the valve box.
  2. Route the sensor cable into the valve box, leaving enough length to reach the right terminal block on the device, the 4-screw terminal block where the 4-wire color-coded cable connects.
  3. Backfill the hole carefully, keeping the sensor vertical and ensuring soil makes contact around all tines without packing too tight. Fill to the surface.

Monitoring every inch of the foundation is impractical and costly. Place devices strategically at points around the foundation where each device and its sensor can represent a distinct zone. A single device can feed several drip emitters or sprinkler heads covering that zone. Position the sensor centrally within the zone at the correct depth to most effectively capture soil moisture and temperature for the area being irrigated. Factor in budget, soil conditions, sun exposure, and foundation layout when deciding placement. Sunny south/west exposures typically dry faster than shaded north/east sides and may need independent monitoring.


Step 5 - Mount and Connect the Device

The device mounts to the underside of the valve box lid on four brass standoffs, hidden inside the box and accessible from the surface. See the Device Mounting Guide for the full step-by-step with hardware details, the process takes about 20 minutes and requires only the included drill template and hex keys.

Ensure power is off at the transformer before making any wiring connections. Turn power back on only after all devices on the run are wired and mounted.

Once the device is mounted to the lid, make the electrical connections. By this point, three cables have been routed into the valve box: the 2-conductor landscape power cable (Step 1), the solenoid 2-wire leads (Step 3), and the 4-wire sensor cable (Step 4). All terminals are labeled on the device rear panel. Use these labels to confirm each connection before applying power. Incorrect wiring has the potential to damage the device, sensor, and/or solenoid.

Right terminal block - soil moisture sensor (4-wire, color-coded):

PinPositionWire colorSignal
4TopBlackGround
3One below topYellowRS485 A
2One above bottomBlueRS485 B
1BottomBrown12VDC out

Sensor leads are color-coded and must be connected by color to the correct terminal. Check all four connections carefully before applying power. Incorrect wiring can damage the device, sensor, or solenoid.

Left terminal block - power and solenoid:

  • Bottom 2 screws: Connect the 2-conductor landscape power cable from the splice connector, either wire to either screw, order does not matter.
  • Top 2 screws: Connect the solenoid wire leads, either wire to either screw, order does not matter.

No polarity requirement means either wire can connect to either terminal for both the power pair and the solenoid leads.

WARNING: Before applying power, confirm that the transformer output tap in use and the solenoid installed in the valve box match. Using the 24 VAC tap with a 12 VDC latching solenoid, or the 12 VAC tap with a 24 VAC hold solenoid, will result in the solenoid failing to open or burning out, and may damage the device.

Splice the landscape cable at this device location using a splice connector. Connect the splice output to the left terminal block bottom screws.

Before closing the lid, verify all connections are secure and confirm the lid closes properly with the device mounted.


Step 6 - Power Up and Verify

  1. Turn on the transformer.
  2. Each device LCD powers on and cycles through startup. After connecting to WiFi and the cloud, the screen cycles live sensor readings, confirming soil moisture, temperature, humidity, and pressure data.
  3. Open the Telemetry Insights app and verify each device appears as online with live telemetry.
  4. Check that soil moisture readings are within a reasonable range, typically 20–80% for most soil types.
  5. Backfill the trench and replace sod or ground cover.
  6. Verify the lid closes properly with the device mounted and all cables clear of the lid seal.

If a device does not come online, check the splice connector for a secure connection and confirm the power cable connection is secure throughout the run.


Products Available from Telemetry Insights

ProductDescription
Transformer300 W, dual-voltage 24/12 VAC output
Landscape cable14–16 AWG multi-conductor, UV-rated
Splice connectorsWaterproof, direct-bury rated
Startup bundleTransformer + cable + connectors in one order

Visit telemetryinsights.com/shop to order.